OMRON
SKU: CP1W9220G
On Order
Programmable Logic Controllers
CP1L-J14DR-A
| Model No | CP1L-J14DR-A |
|---|---|
| SKU | CP1W9220G |
| Category | Programmable Logic Controllers |
Specifications
| Model | Compact |
|---|---|
| Height | 90 mm |
| Depth | 85 mm |
| With display | No |
| Suitable for safety functions | No |
| Number of digital inputs | 8 |
| Number of digital outputs | 6 |
| Number of analogue inputs | 0 |
| Number of analogue outputs | 0 |
| Voltage type (supply voltage) | AC/DC |
| Type of memory | FLASH |
| Memory size | 64 kByte |
| Supporting protocol for LON | No |
| Number of HW-interfaces industrial Ethernet | 0 |
| Number of HW-interfaces RS-232 | 0 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 0 |
| Number of HW-interfaces USB | 1 |
| Number of HW-interfaces parallel | 0 |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Additional program memory possible | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for ASI | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | No |
| Redundancy | No |
| Suitable for rail mounting | Yes |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| System accessory | No |
| Appendant operation agent (Ex ia) | No |
| Appendant operation agent (Ex ib) | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for INTERBUS-Safety | No |
| Number of interfaces PROFINET | 0 |
| Number of HW-interfaces wireless | 0 |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Wall mounting/direct mounting | Yes |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| IO link master | No |
| Number of relay outputs | 6 |
| Performance level according to EN ISO 13849-1 | Level a |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supply voltage AC 50 Hz | 85 V |
| Supply voltage AC 60 Hz | 85 V |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| SIL according to IEC 61508 | None |
| Supporting protocol for IEC 61850 Ethernet | No |
| Supporting protocol for DNP3 | No |
| Supporting protocol for IEC 60870 | No |
| Supporting protocol for EtherCAT | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location group F (carbonaceous dusts) | No |
| Certified for UL hazardous location group G (non-conductive dusts) | No |
Technical data supplied by OMRON and classified to ETIM 10.