OMRON
SKU: NX1WADB21
On Order
NX1W-ADB21 – Sysmac NX1P Analog I/O vidasız opsiyon kartı, 2 x analog giriş 0 to 10 V, çözünürlük 1/4000 veya 0 to 20 mA, çözünürlük 1:2000
NX1W-ADB21
| Model No | NX1W-ADB21 |
|---|---|
| SKU | NX1WADB21 |
| HS Code | 8471.6070.00 |
| Category | Input and Output |
Description
Sysmac NX1P Analog I/O vidasız opsiyon kartı, 2 x analog giriş 0 to 10 V, çözünürlük 1/4000 veya 0 to 20 mA, çözünürlük 1:2000
Specifications
| Model No | NX1W-ADB21 |
| SKU | NX1WADB21 |
| HS CODE | 8471.6070.00 |
| DATA SHEET | Datasheet (EN) |
Specifications
| Product Type | Sysmac NX1P Analog I/O screwless option card |
|---|---|
| Input | 2 x analog input 0 to 10 V |
| Resolution | resolution 1/4000 veya 0 to 20 mA |
| Width | 35 mm |
| Height | 35 mm |
| Depth | 27 mm |
| Suitable for safety functions | No |
| Number of analogue inputs | 2 |
| Number of analogue outputs | 0 |
| Voltage type (supply voltage) | DC |
| Supporting protocol for LON | No |
| Number of HW-interfaces industrial Ethernet | 0 |
| Number of HW-interfaces RS-232 | 0 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 0 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces USB | 0 |
| Number of HW-interfaces parallel | 0 |
| Number of HW-interfaces other | 1 |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for ASI | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | No |
| Input, current | Yes |
| Input, voltage | Yes |
| Input, resistor | No |
| Input, resistance thermometer | No |
| Input, thermocouple | No |
| Input signal, configurable | Yes |
| Output, current | No |
| Output, voltage | No |
| Output signal configurable | No |
| Resolution of the analogue inputs | 12 Bit |
| Type of electric connection | Spring clamp connection |
| Suitable for rail mounting | Yes |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| Fieldbus connection over separate bus coupler possible | Yes |
| System accessory | No |
| Appendant operation agent (Ex ia) | No |
| Appendant operation agent (Ex ib) | No |
| Degree of protection (IP) | IP20 |
| Supporting protocol for SERCOS | No |
| Supporting protocol for INTERBUS-Safety | No |
| Number of interfaces PROFINET | 0 |
| Number of HW-interfaces wireless | 0 |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Wall mounting/direct mounting | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| IO link master | No |
| Performance level according to EN ISO 13849-1 | Level a |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supply voltage DC | 20.4 V |
| Analogue inputs configurable | No |
| Analogue outputs configurable | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| SIL according to IEC 61508 | None |
| Degree of protection (NEMA) | Other |
| Supporting protocol for EtherCAT | Yes |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location group F (carbonaceous dusts) | No |
| Certified for UL hazardous location group G (non-conductive dusts) | No |
Technical data supplied by OMRON and classified to ETIM 10.